6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations

6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations

Product Details:

Place of Origin: China
Brand Name: TIAN RUI
Certification: ROHS REACH
Model Number: 2RB-6SS Series

Payment & Shipping Terms:

Minimum Order Quantity: 1000PCS
Price: Negotiable
Packaging Details: 1000pcs/PE bag
Delivery Time: 5-7 days
Payment Terms: D/P,T/T,Paypal,Western Union
Supply Ability: 1000000+PCS+Month
Get Best Price Contact Now

Detail Information

Type: Ceramic Gas Discharge Tube Material: Ceramics
Dc Spark-over Voltage: 230V Operating Temperature: -40℃ To +90℃
8/20μs Impulse Current Capability: 10kA Size: 6.2mmX6mm
Application Area: Power Supplies Utra Low Compliance: <1.5pF
Lead: Lead-free Response: Excellent
Highlight:

6.2mmx6mm Ceramic Gas Discharge Tube

,

Base Stations Ceramic Gas Discharge Tube

,

10kA Surge Protector GDT

Product Description

 
2RB-6SS Series 6.2mmx6mm Impulse Current Capability 10kA GDT Gas Discharge Tube Arresters for Base Stations
 
Description
 

Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes. The ceramic envelope and with nickel connectors allow for high loads. 2RB-6SS Gas Discharge Tubes (GDT) series has a surge rating of 10kA, 8/20μs.Offered in a Squared Surface Mount package, which helps to make pick and place on PCB process easier.

 

This GDT series is perfectly suited for broadband equipment applications. The GDT’s low off-state capacitance is compatible with high bandwidth applications and this capacitance loading value does not vary if the voltage across the GDT changes.
2RB-6SS Gas Discharge Tube (GDT) series are specifically designed for protection of electrical, multimedia, and communication equipment against over voltage transients in
surface mount assembly applications.

 

6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations 0

 

 
Features
 
 Excellent response to fast rising transients

 Stable breakdown voltage

 GHz working frequency

 8/20μs Impulse current capability: 10KA

 Non-Radioactive

 Ultra Low capacitance (<1.5pF)

 Lead-free compliant

 RoHS and REACH compliant

 Size: □6.2mm*6mm

 Storage and operational temperature: -40~+90°C
 
Applications
 
 MDF modules

 xDSL equipment

 RF systems

 Antenna

 Base stations

 Repeaters, Modems

 Telephone Interface, Line cards
 
 Data communication equipment

 Line test equipment

 Power supplies

 Surge protectors, Alarm systems
 
Part Number Code
 
6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations 1
Electrical Characteristics
 
Part Number DC
Spark-over Voltage 1) 2) @100V/S
Impulse Spark-over Voltage Insulation Resistance
3)
Capacitance @1MHz Life Ratings
Impulse Discharge Current @8/20μS AC Discharge Current @50Hz 1S Impulse Life @10/1000μS 100A
100V/μS 1KV/μS
Max Max Min Max Nominal
±5 times
Max 1 time Nominal 5 times Min
V V V pF KA KA A Times
2R075B-6SS 75±20% 500 600 1 1.5 10 15 10 300
2R090B-6SS 90±20% 500 600 1 1.5 10 15 10 300
2R150B-6SS 150±20% 500 600 1 1.5 10 15 10 300
2R230B-6SS 230±20% 600 700 1 1.5 10 15 10 300
2R250B-6SS 250±20% 600 700 1 1.5 10 15 10 300
2R300B-6SS 300±20% 750 850 1 1.5 10 15 10 300
2R350B-6SS 350±20% 800 900 1 1.5 10 15 10 300
Glow Voltage at 10mA ~60V
Arc Voltage at 1A............................................................................... ~10V
Glow to Arc transition Current ~1.0A
Weight…………………………………………………………………...... ~0.8g
Operation and storage temperature……………………………………. -40~+90°C
Climatic category (IEC 60068-1)……………………………………….. 40/90/21
Surface treatment……………………………………………………...... Matte-tin plated

 

1) At delivery AQL 0.65 level II, DIN ISO 2859


2) In ionized mode


3) Insulation Resistance Measuring Voltage:
75V at DC 25V
90V~150V at DC 50V
Other at DC 100V


Terms in accordance with ITU-T Rec. K.12, IEC 61643-311, GB/T 9043.

 

Dimensions

 

6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations 2

 

Symbol Millimeters Inches
A 6.2±0.2 0.244±0.008
B 6.2±0.2 0.244±0.008
C 6±0.3 0.236±0.012
D 0.6±0.1 0.024±0.004
E 6.1±0.1 0.240±0.004
F 7.5±0.2 0.295±0.008
X 1.3 0.051
X1 5.8 0.228
Y 7.0 0.276

 

Taping and Reel Specifications

 
6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations 3

 

Symbol Millimeters Inches
W 16±0.3 0.630±0.012
A0 6.5±0.1 0.256±0.004
B0 6.3±0.1 0.248±0.004
K0 6.4±0.1 0.252±0.004
P 12±0.1 0.472±0.004
F 7.5±0.1 0.295±0.004
E 1.75±0.1 0.069±0.004
D 1.5+0.1/-0.0 0.059+0.004/-0.0
P0 4±0.1 0.157±0.004
P2 2±0.1 0.079±0.004
T 0.5±0.1 0.020±0.004
D0 13.3±0.15 0.524±0.006
D1 330±2 12.992±0.079
D2 100+1/-2 3.937+0.039/-0.079
W1 16.5±0.4 0.65±0.016

 

Soldering Parameters - Reflow Soldering (Surface Mount Devices)

 
6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations 4
Reflow Condition Pb - Free assembly
Pre Heat -Temperature Min (Ts(min)) 150°C
-Temperature Max (Ts(max)) 200°C
- Time (min to max) (ts) 60 -180 Seconds
Average ramp up rate ( Liquids Temp TL) to peak 3°C/second max
TS(max) to TL - Ramp-up Rate 5°C/second max
Reflow - Temperature (TL) (Liquids) 217°C
- Time (min to max) (ts) 60 -150 Seconds
Peak Temperature (TP) 260 +0/-5°C
Time within 5°C of actual peak Temperature (tp) 10 - 30 Seconds
Ramp-down Rate 6°C/second max
Time 25°C to peak Temperature (TP) 8 minutes Max
Do not exceed 260°C

 

 

Want to Know more details about this product
I am interested in 6.2mmx6mm Ceramic Gas Discharge Tube 10kA Surge Protector GDT For Base Stations could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.