High Breaking Capacity High Voltage HV Current Limiting Cut Out Fuse Clip
Product Details:
Place of Origin: | China |
Brand Name: | Tian Rui |
Certification: | ROHS |
Model Number: | XRNP1 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1000PCS |
---|---|
Price: | Negotiable |
Packaging Details: | 1000PCS/Bag |
Delivery Time: | 5-7 Days |
Payment Terms: | D/P, T/T,Paypal, Western Union |
Supply Ability: | 1000000PCS/Month |
Detail Information |
|||
Product Name: | Limiting Fuse Clip | Rated Voltage: | 3.6- 40.5KV |
---|---|---|---|
Rated Frequency: | 50HZ | Breaking Current: | 63KV |
Ambient Temperature: | -30°C To +40°C | Altitude: | Not More Than 1000m |
Error: | Less Than ±10% | Application: | Overload And Short Circuit Protection |
Usage Scenario: | Outdoor | Standard: | GB15166.2 IEC282-1 |
Highlight: | 63KV Fuse Clip,40.5KV Fuse Clip,3.6KV Fuse Clips |
Product Description
High Breaking Capacity High Voltage HV Current Limiting Cut Out Fuse Clip
Description
This product is suitable for indoor AC 50HZ, rated voltage 3.6-40.5KV system as overload and short circuit protection of voltage transformer. (Passed the type test of the National High-voltage Electrical Appliance Quality Supervision and Testing Center, and the product complies with GB15166.2 and IEC282-1).
Parameters
Part No. | XRNP1 |
Product Name | Limiting Fuse Clip |
Rated Voltage | 3.6- 40.5KV |
Rated Frequency | 50HZ |
Breaking Current | 63KV |
Ambient Temperature | -30°C to +40°C |
Altitude | Not More Than 1000m |
Application | Overload and Short Circuit Protection |
Usage Scenario | Outdoor |
Features
1. High breaking capacity, breaking current up to 63KV.
2. Low power consumption and low temperature rise.
3. The action is very fast, and the one-second characteristic is faster than that of similar products currently produced in China. For example, a fuse link with a rated current of 100A is connected to an expected current of 1000A, and the pre-arc time does not exceed 0.1S+
4. An one-second characteristic error is less than +10%.
5. Equipped with a spring-type impactor, the impactor has the advantages of large contact surface and low pressure. Therefore, when the switch is pushed for interlocking action, the contact surface between the switch and the striker will not be broken or broken.
6. Standardization of specifications.
7. It has a larger current limiting effect.
8. Product performance conforms to GB15166.2 national standard and IEC60282-1 international standard.
9. It can reliably break any fault current between the minimum breaking current and the rated breaking current. In addition, various non-standard products can also be produced according to user needs