Metal Nut Screw 24VDC Thermal Circuit Breaker Manual Reset Single Pole
Product Details:
Place of Origin: | China |
Brand Name: | Tian Rui |
Certification: | CUL UL TUV CCC VDE |
Model Number: | 91 Series |
Payment & Shipping Terms:
Minimum Order Quantity: | 1000PCS |
---|---|
Price: | Negotiable |
Packaging Details: | 100PCS/Bag |
Delivery Time: | 5-7 Days |
Payment Terms: | D/P, T/T,Paypal, Western Union |
Supply Ability: | 1000000PCS/Month |
Detail Information |
|||
Rated Current: | 0.5A-10A | Rated Voltage: | 125/250VAC, 50VDC |
---|---|---|---|
Reset Type: | Puse To Reset | Pole: | Single Pole |
Test Environment Temperature: | 25℃±3℃ | Dielectric Strength: | >1500VAC/Min |
Insulation Resistance: | >100MOHM (DC 500V) | Typical Life: | 1,000 Operations At 200% Overload |
1,000 Operations At 200% Overload: | 125/250CACx1,000A(UL 1077) | Packing: | Bulk, Plastic Bag |
Highlight: | 24VDC Thermal Circuit Breaker,0.5A Thermal Circuit Breaker,VDE Single Pole Circuit Breaker |
Product Description
91 Series Electronic Metal Nut Screw 24V DC Manual Reset Mini Thermal Single Pole Circuit Breaker
Technical Data
Current rating range | 0.5~10A |
Input voltage rating | 125/250VAC;50VDC |
Interrupting Capacity | 125/250CACx1,000A(UL 1077) |
Typical Life | 1,000 operations at 200% overload |
Insulation co-ordination | Rated impulse withstand voltage 2.5kV |
Dielectric Strength | >1.500VAC/min |
Insulation Resistance | >100MOHM (DC 500V) |
Degree of protection | Terminal area IP00,operating area IP40 |
How to Select the Current
Generally, it is recommended to choose about 1.5 times the rated current. For example, if the rated current is 1A, and the actual abnormal current fluctuation reaches 1.5A, 1.5A is appropriate; if the abnormal current reaches 2A, 2A is appropriate. The time of tripping (that is, disconnection) is determined by exceeding the selected A number. If the actual current exceeds the greater, the faster the trip will be. It is not immediately disconnected after exceeding the selected A number. The specific trip time is as follows:
Calibration(at25℃)
100%of Rated Current | Hold,No Trip |
150%of Rated Current | Trip Within 1Hour |
175%of Rated Current | 2.0-10.0 sec Trip |
200%of Rated Current | 1.1-5.0 sec Trip |
Approval
Approval & File NO | Rated current | Rated voltage |
CUL UL E155159 | 0.5-10.0A | 125/250VAC;50VDC |
TUV SUD B150158611006 | 0.5-10.0A | 125/250VAC;50VDC |
CCC 201101030752058 | 1.0-10.0A | 125/250VAC |
VDE 40036160 | 1.0-10.0A | 125/250VAC |
Max.Internal Resistance | |
1.0- 2.0Amp | 0.175 Ohm |
2.1-3.0Amp | 0.125 Ohm |
3.1-3.7Amp | | 0.050 Ohm |
3.8-5.0Amp | 0.040 Ohm |
5.1-7.0Amp | 0.030 Ohm |
7.1- 10.0Amp | 0.020 Ohm |
Mechanical/Environmental Data
Operating Ambient Temperature: -10℃ to +60℃ Mounting: Various options. See Ordering Information and drawings
Termination: 250’’(6.35mm)quick connects or solder terminals
Product Life
The number of mechanical actions is more than 3000 times, and the current impact of 6 times is more than 50 times.
Wiring Mode
Regardless of the positive and negative poles, just like a switch, the end is in and the end is out, that is, in series, the pins can be welded or 2.8MM plug springs can be used.
Typical Applications
Tarnsforms, Motors, Battery chargers, Power supplies,
appliances, extra low voltage systems, machinery.
The Difference Between Automatic Reset and Manual Reset
After the over-current protector is tripped (disconnected), manual reset (on) requires the actual current to be reset within the selected current by pressing the button. For automatic reset, the actual current will automatically reset within 60 seconds of the selected current. There is no button for automatic reset, no head, 91 series are manual reset.