Product Name: GDT Gas Discharge Tubes For Telecom Equipment Type: Gas Discharge Tube Arresters
Material: Ceramics Dc Spark-over Voltage: 75V To 800V
Tolerance: 20% Working Frequency: Ghz
Max. Capacitance(1MHz): 1pF Impulse Life(10/1000μs)(100A): 300 Times
Impulse Discharge Current(8/20μs): 5kA Sample: Free
High Light:

Telecom Equipment GDT Gas Discharge Tube

,

5KA GDT Gas Discharge Tube

,

3600V Gas Discharge Tube Arresters

Product Description

 

2RA-5 Series Telecom Applications 75V-800V GDT Surge Protector Arrestor 5KA Gas Discharge Tube Arresters

 

Description


GDT is placed in front of, and in parallel with, sensitive telecom equipment such as power lines, communication lines, signal lines and data transmission lines to help protect them from damage caused by transient surge voltages that may result from lightning strikes and equipment switching operations. These devices do not influence the signal in normal operation.
However, in the event of an overvoltage surge, such as a lightning strike, the GDT switches to a low impedance state and diverts the energy away from the sensitive equipment.

 

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 0

 

Features

 

 Excellent response to fast rising transients

 

 Stable breakdown voltage


 GHz working frequency


 8/20μs Impulse current capability: 5KA


 Non-Radioactive


 Ultra Low capacitance (<1pF)


 Lead-free compliant


 RoHS and REACH compliant


 UL 497B Recognized: E465335


 Size: Ф5.5mm*6mm


 Storage and operational temperature: -40~+90°C

 

Applications

 

 CATV equipment


 Antennas


 RS 485


 Telecom Base Station


 Power Supply AC Main


 EV power Charging


 Inverter/Variable


 Frequency Drivers (VFDs)


 IEEE 802.3 compliant Ethernet interfaces

 

 Broad Band equipment


 xDSL, ADSL, ADSL2, VDSL, and VDSL2


 Medical Electronics


 Test Equipment


 General Telecom Equipment


 Renewable Energy

 

Part Number Code

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 1

Electrical Characteristics

 

Part Number DC
Spark-over Voltage 1) 2) @100V/S
Impulse Spark-over Voltage Insulation Resistance
3)
Capacitance @1MHz Life Ratings
Impulse Discharge Current @8/20μS AC Discharge Current @50Hz 1S Impulse Life @10/1000μS 100A
100V/μS 1KV/μS
Max Max Min Max Nominal
±5 times
Max 1 time Nominal 5 times Min
DIP SMD V V V pF KA KA A Times
2R075TA-5 2R075SA-5 75±20% 500 600 1 1 5 10 5 300
2R090TA-5 2R090SA-5 90±20% 500 600 1 1 5 10 5 300
2R150TA-5 2R150SA-5 150±20% 500 600 1 1 5 10 5 300
2R230TA-5 2R230SA-5 230±20% 600 700 1 1 5 10 5 300
2R250TA-5 2R250SA-5 250±20% 600 700 1 1 5 10 5 300
2R300TA-5 2R300SA-5 300±20% 750 850 1 1 5 10 5 300
2R350TA-5 2R350SA-5 350±20% 800 900 1 1 5 10 5 300
2R400TA-5 2R400SA-5 400±20% 850 950 1 1 5 10 5 300
2R420TA-5 2R420SA-5 420±20% 850 950 1 1 5 10 5 300
2R470TA-5 2R470SA-5 470±20% 900 1000 1 1 5 10 5 300
2R600TA-5 2R600SA-5 600±20% 1000 1200 1 1 5 10 5 300
2R800TA-5 2R800SA-5 800±20% 1200 1400 1 1 5 10 5 300
Glow Voltage at 10mA........................................................................ ~60V
Arc Voltage at 1A ~10V
Glow to Arc transition Current………………………………………...... ~0.5A
Weight…………………………………………………………………...... DIP ~0.82g
SMD ~0.55g
Operation and storage temperature……………………………………. -40~+90°C
Climatic category (IEC 60068-1) 40/90/21
Surface treatment……………………………………………………...... DIP -Nickel Plated
SMD -Matte-tin plated

 

1) At delivery AQL 0.65 level II, DIN ISO 2859


2) In ionized mode


3) Insulation Resistance Measuring Voltage:
75V at DC 25V
90V~150V at DC 50V
Other at DC 100V


Terms in accordance with ITU-T Rec. K.12, IEC 61643-311, GB/T 9043.

 

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 2

 

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 3

Packaging Quantity:


100 PCS per Plastic Tray


5 Plastic Trays per inner box 500 PCS per inner box

 

Axial Packaging (Tape & Reel)

 

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 4

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 5

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 6

Soldering Parameters - Wave soldering (Thru-Hole Devices)

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 7
Wave Soldering Condition Pb-Free assembly
Preheat Temperature Min 100°C
Temperature Max 150°C
Time (Min to Max) 60-180 Seconds
Solder Pot Temperature 280°C Max
Solder Dwell Time 2-5 Seconds

 

Soldering Parameters - Reflow Soldering (Surface Mount Devices)

75V-800V 5KA GDT Gas Discharge Tube Arresters For Telecom Equipment 8
Reflow Condition Pb - Free assembly
Preheat -Temperature Min (Ts(min)) 150°C
-Temperature Max (Ts(max)) 200°C
- Time (min to max) (ts) 60 -180 Seconds
Average ramp up rate ( Liquids Temp TL) to peak 3°C/second max
TS(max) to TL - Ramp-up Rate 5°C/second max
Reflow - Temperature (TL) (Liquids) 217°C
- Time (min to max) (ts) 60 -150 Seconds
Peak Temperature (TP) 260 +0/-5°C
Time within 5°C of actual peak Temperature (tp) 10 - 30 Seconds
Ramp-down Rate 6°C/second max
Time 25°C to peak Temperature (TP) 8 minutes Max
Do not exceed 260°C

 

 

 