Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead

Product Details:

Place of Origin: China
Brand Name: Tian Rui
Certification: cURus, CQC, PSE, TUV, cULus
Model Number: 331 311 Series

Payment & Shipping Terms:

Minimum Order Quantity: 1000PCS
Price: Negotiable
Packaging Details: 1000PCS/Bag
Delivery Time: 5-7 Days
Payment Terms: D/P, T/T,Paypal, Western Union
Supply Ability: 1000000PCS/Month
Get Best Price Contact Now

Detail Information

Rated Current: 250mA-12A; 500mA-10A Rated Voltage: 250V AC
Tube: Glass Tube End Cap: Nickel Plated Brass
Axial Lead: Tin Plated Copper Wires Type: Fast Acting
Main Characteristics: Subminiature Cartridge Fuse; Fast- Acting(F) Standard: UL248-14; IEC60127-3
Operating Temperature: -55℃ To +125℃ Storage Conditions: +10℃ To +60℃
High Light:

250V Quick Blow Fuse

,

3.6 X10mm Quick Blow Fuse

,

Cartridge 3.6 X10mm Fuse

Product Description

Electrical Axial Lead 250V Cartridge Quick Blow Fast Acting 3.6x10mm Tube Glass Fuse

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 0

 

Series:3.6x10mm tube glass fuse
Product keyword:NO.331/3.6*10mm 3.6x10mm glass fuse

 

331 series are fast-acting and low breaking capacity fuses, suitable for 250V AC voltage, breaking capacity less than 63A protection circuit.
331 series fuses are mainly used in lighting, power supply and power adapters.

 

Time-current characteristics: fast fusing (F)
Dividing ability: 50A@125Vac[250mA~6.3A], 35A or 10In@250Vac[250mA~6.3A], 50A@250Vac[7~10A]


Standard: UL 248-14


Accredited: cURus, CQC, PSE, TUV


Material: shell-glass tube, metal cap-nickel-plated brass, lead cap-nickel-plated cap, tin-plated copper wire


Operating temperature: -55℃ ~ +125℃


Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds (manual welding)


Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;


Storage condition: +10℃ ~ +60℃;The annual average relative humidity is less than 75%, and the relative humidity reaches 95% for a maximum of not more than 30 days

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 1

 

Time vs Current Characteristics: UL248-14
Rated Current 150% 210% 275% 400% 1000%
250mA~5A >1h <30min 10ms~3s 3ms~300ms ≤20ms
6.3A~10A >1h <30min 50ms~10s 5ms~400ms ≤20ms

 

Electrical Characteristics at 25℃
Amp
Code
Ratede
Current
Max
Voltage
Drop(mV)

 

Max.Power
Dissipation
(mW)
Typical
cold Resistance(mΩ)
Nominal Melting
I²t(A²sec)
Breaking
Capacity

Approvals

             
cULus
PSE TUV CCC
              125V 250V 250V 250V 250V
0500 500mA 350 459 137.80 0.384

 

 
50A/125V AC
35A or 10ln/250V AC








 

0630 630mA 320 529 95.23 0.656
0800 800mA 300 630 123.75 1.00
1100 1.00A 280 375 55.00 2.25
1125 1.25A 280 919 43.00 2.57
1160 1.60A 250 1050 37.80 2.89
1200 2.00A 240 1260 26.00 2.25
1250 2.50A 200 1313 19.90 6.75
1315 3.15A 180 1488 15.00 13.69
1400 4.00A 160 1680 11.22 22.09
1500 5.00A 150 1969 8.78 39.69
1630 6.30A 150 1969 7.00 62.41
1800 8.00A 150 1969 5.83 92.16
50A/125V AC
50A/250V AC
2100 10.00A 150 1969 4.80 156

 

Note: 1.Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)
          2.The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 2

 

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 0

 

Series:3x10mm tube glass fuse
Product keyword:NO.311/3*10mm fast acting glass fuse

 

Series 311 are fast blow and low breaking capacity fuses, suitable for 250V AC voltage, breaking capacity less than 50A protection circuit.
311 series fuses are mainly used in lighting, power supply and power adapters.

 

Time-current characteristics: fast-acting fusing (F)
Dividing ability: 50A@250Vac / 50A@125Vac

 

Standard: UL 248-14


Accredited: cULus


Material: shell - glass tube, metal cap - nickel plated brass, lead cap - nickel - plated cap, tin - plated copper wire


Operating temperature: -55℃ ~ +125℃


Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds (manual welding)


Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;


Storage condition: +10℃ ~ +60℃;The annual average relative humidity is less than 75%, and the relative humidity reaches 95% for a maximum of not more than 30 days

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 4

Time vs Current Characteristics: UL248-14
Rated Current 100% 200%
250mA~12A >4h <5s

 

Electrical Characteristics at 25℃
Amp Code
Ratede Current
Rated Voltage
Typical
cold Resistance(mΩ)
Nominal Melting
I²t(A²sec)
Breaking
Capacity
Approvals
   




 

 

 

 

 

 

 

 

 

250V AC














 

   

 
 
 
 
 
 
 
 
 
 
50A @ 250V AC
50A @ 125V AC













 
cULus
0250 250mA 540 0.040
125V
250V
0300 300mA 335 0.078
0500 500mA 182 0.225
0630 630mA 145 0.357
0800 800mA 131 0.576
1100 1.00A 70.0 0.940
1125 1.25A 62.8 1.56
1150 1.50A 52.0 3.45
1200 2.00A 31.5 6.25
1250 2.50A 32.3 4.00
1300 3.00A 22.0 11.9
1315 3.15A 23.1 4.97
1400 4.00A 15.5 7.84
1500 5.00A 12.0 20.3
1630 6.30A 9.73 34.5
1700 7.00A 8.20 48.8
1800 8.00A 7.80 64.0
2100 10.00A 6.31 81.0
2120 12.00A 5.31 132

 

Note: 1.Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)
          2.The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 5

 

 

Contact Details:

Andy Wu

Email: andy@tianrui-fuse.com.cn

MP/Whatsapp: +86 13532772961

Wechat: HFeng0805

Skype: andywutechrich

QQ: 969828363

 

 

 

 

 

 
 

Want to Know more details about this product
I am interested in Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.