AUPO BF系列温度保险丝
|
新型号 |
额定动
作温度 |
动作精度 |
保持
温度 |
极限
温度 |
额定
电流 |
额定
电压 |
安规认证 |
RoHS
符合品 |
|
UL |
VDE |
PSE |
CCC |
|
BF73 |
73℃ |
70±2℃ |
45℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF77 |
77℃ |
76+0/-4℃ |
51℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF84 |
84℃ |
82±2℃ |
58℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF94 |
94℃ |
93+1/-3℃ |
66℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF99 |
99℃ |
96±2℃ |
71℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF104 |
104℃ |
100±2℃ |
79℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF113 |
113℃ |
109+3/-1℃ |
84℃ |
150℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF117 |
117℃ |
115±2℃ |
92℃ |
160℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF121 |
121℃ |
119±2℃ |
94℃ |
160℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF133 |
133℃ |
129±2℃ |
104℃ |
160℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF142 |
142℃ |
139±2℃ |
114℃ |
160℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF157 |
157℃ |
152±2℃ |
127℃ |
172℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF172 |
172℃ |
169+3/-1℃ |
144℃ |
189℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF184 |
184℃ |
182+1/-3℃ |
159℃ |
210℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF192 |
192℃ |
188+3/-1℃ |
170℃ |
300℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF216 |
216℃ |
214+1/-3℃ |
191℃ |
380℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF229 |
229℃ |
226+3/-2℃ |
200℃ |
380℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
BF240 |
240℃ |
235±3℃ |
200℃ |
380℃ |
10A |
250Vac |
● |
● |
● |
● |
● |
|
[0000].jpg) |

 |
术语解释
|
额定动作温(TF): |
温度保险丝按标准规定方法测试,改变其导电状态的温度。按基于IEC691的安全标准
规定,温度保险丝必须在上述温度+0/-10℃范围内动作。(日本电气用品管理法规定公差范围为+/-7℃范围内动作)。 |
|
实测动作温度:
|
温度保险丝在硅油池内以每分钟0.5-1℃速率升温,检测电流小于100mA条件下所测得的熔断温度。它是温度保险丝的实际动作温度。 |
|
保持温度(TH):
|
温度保险丝在通过额定电流时,能保持168小时而不会改变其导电状态的最高温度。
|
|
极限温度(TM):
|
温度保险丝能承受10分钟而不曾发生重新接通现象的最高温度。 |
|
额定电流(Ir):
|
温度保险丝能承载的最大电流。 |
|
额定电压(Ur):
|
温度保险丝最高工作电压。 |
|